src.dualinventive.com/go/cp3000-interface/CHANGELOG.md

3.7 KiB

Changelog

All notable changes to this project will be documented in this file.

The format is based on Keep a Changelog and this project adheres to Semantic Versioning.

[1.6.2] - 2019-05-29

Added

  • device base: Add mutex for synchronisation for the CP3000 client when request-reply action is performed (MWL-83)

Changed

  • zkl3000rc: Add extra retries for ZKL switch info request with exponential backoff (MWL-83)

Removed

  • Configuration option zkl3000rc_maximum_wait_for_measurement for the ZKL 3000 RC device waiting for measurement which may not be changed (MWL-83)

[1.6.1] - 2019-05-29

Changed

  • Change device base timeout default to 10 seconds (was 6 seconds) which is the same as legacy secure server (BACKEND-402)
  • Change ZKL 3000 RC MaximumWaitForMeasurement from 3 seconds (was 30 seconds) (BACKEND-402)

Added

  • Add configuration option device_command_timeout for the device base CP3000 reqrep timeout (BACKEND-402)
  • Add configuration option zkl3000rc_maximum_wait_for_measurement for the ZKL 3000 RC device waiting for measurement (BACKEND-402)

Fixed

  • Speed up unit tests of the ZKL 3000 RC device after introduction of MaximumWaitForMeasurement (BACKEND-402)

[1.6.0] - 2019-05-23

Changed

  • Only log DI-Net error 1041 measurement error as warning and don't raise device error (BACKEND-401)

Added

  • Added new device types: ZKL3000 USA, RSS 3000, ZKL 3000 RC USA, RCS 3000, ZKL 3000 RCC USA, CRTM 3000 (BACKEND-394)

[1.5.2] - 2019-05-15

Changed

  • Allow deactivate and return with device errors (BACKEND-397)

[1.5.1] - 2019-04-25

Changed

[1.5.0] - 2019-04-16

Added

  • After a failed switch of a ZKL 3000 RC wait for set number of retries before sending reply to SMP (BACKEND-349)
  • Raise response error when keyswitch is unknown (BACKEND-353)
  • Allow release with the same token (BACKEND-354)
  • Check detection status after activate (BACKEND-356)
  • Check if device is indeed switched on after activate (BACKEND-357)
  • Check if device is indeed switched off after deactivate (BACKEND-358)

[1.4.1] - 2019-03-26

Fixed

  • Fixed Gorm column reference to sms_mo (BACKEND-362)

[1.4.0] - 2019-03-19

Added

  • Added new sensor values (rms, ba-autocal, temp-onboard and temp-ntc) for ZKL 3000 & ZKL 3000 RC & ZKL 3000 RCC (BACKEND-288)
  • Correct error and warning handling for ZKL 3000 RC (BACKEND-337)

[1.3.0] - 2019-03-11

Added

  • Added reset SMS (t-mobile) (BACKEND-289)

[1.2.2] - 2019-01-31

Fixed

  • The order of the reset vodafone request is now always the same

[1.2.1] - 2019-01-31

Fixed

  • Bug when vodafone reset SMS succeeds, the code think it fails

[1.2.0] - 2019-01-30

Added

  • Added reset SMS (vodafone) (BACKEND-174)

[1.1.0] - 2019-01-21

Added

  • Added battery checks (BACKEND-255)
  • Raise a warning when a short is already detected when activating a ZKL 3000 RC (BACKEND-175)
  • Raise a warning when a short is still detected after deactivating a ZKL 3000 RC (BACKEND-273)

[1.0.1] - 2018-10-30

Fixed

  • Added unit tests (BACKEND-173)
  • ZKL3000(RC): Only send detection quality when the switch is on (BACKEND-228)
  • Close the connection when a read deadline is reached (BACKEND-225)

[1.0.0] - 2018-10-08

Fixed

  • ZKL3000RC: Device state will updated when you do config:set/config:reset (BACKEND-218)
  • ZKL3000RC: Sensor:info returned always iofailed (BACKEND-266)

[0.1.0] - 2018-08-07

Initial release of v0.1.0