# Change Log All notable changes to this project will be documented in this file. The format is based on [Keep a Changelog](http://keepachangelog.com/). ## [v2.4] - 2019-04-16 ### Added - Added four extra test points on the bottom copper layer for the section-to-section resistive test. (TP20, TP21, TP76, TP77). Copper change only, nothing else moved. ## [v2.3] - 2019-03-20 ### Changed - The Drive and Measure MCUs now have a control pin to control their Listen/Send status on the CAN Bus - The Control MCU now also has a pin to control its Listen/Send status on the CAN Bus - R162 and R159 were changed from 10k to 18k to allow better listen/send control - Enabled some quite sensible design rules that were apparently never enabled. Then also cleaned up the mess it found. ### Added - R19 to improve Listen/Send control from the Control MCU - A very large number of test-pads to facilitate production test/test-ok. ## [v2.2] - 2019-01-16 ### Changed - Switch input signals were modified to have double caps, to avoid leakage current through wear or damage, simultaneously the diodes were replaced by TVS clamping diodes. ## [v2.1] - 2018-11-26 ### Added - Thermal Sensor ## [v2.0] - 2018-06-18 ### Changed - Changed all components to DI library based. - Changed several pull-ups to 100k for power saving. ### Added - Added an I2C Thermal Sensor to the Control microcontroller. - Added an 5V enable signal on pin PA07 - Minor Version resistors allowing 8 levels of minor version. - Variants - Labeling of "DRV/MEAS/CTRL" to the board next to headers and processors. ### Removed - Removed the individual control of all CAN enable and on/off lines and combined them all to IO pin PA06. - Removed the versioning on the Drive and Measure processors, as these make hardly any sense.